BJSBX - SAFETY ORANGE SPEEDTEC EQUIP ENAMEL 313-23

  • MSDS: BJSBX
  • Manufacturer: O'BRIEN CORP
  • Product Name: SAFETY ORANGE SPEEDTEC EQUIP ENAMEL 313-23
  • National Stock Number: 8010-00N012358
Product Identification

Product ID:SAFETY ORANGE SPEEDTEC EQUIP ENAMEL 313-23
MSDS Date:10/18/1986
FSC:8010
NIIN:00N012358
MSDS Number: BJSBX

Responsible Party
O'BRIEN CORP
450 E GRAND AVE
SOUTH SAN FRANCISCO, CA 94080
US

Emergency Phone: 415-761-2300; 800-424-9300 CHEMTREC

Info Phone: 415-761-2300

Cage: FO983

Contractor
O'BRIEN CORP
SOUTH SAN FRANCISCO, CA 94080 US

Telephone: (415) 761-2300

Cage: FO983

Ingredients

ENCEPHALOPATHY MAY RESULT.CR (VI) IS CARCINOGENIC & MAY

RTECS: 9999999ZZ


INGEST AS ROUTE OF ENTRY FOR LEAD . RPTD/PRLNGD OVEREXP TO

RTECS: 9999999ZZ


(NAPHTHA, MEDIUM ALIPHATIC F ), VAPOR PRESSURE = 5.00

CAS: 64742-88-7

Fraction By Weight: 25%


LEAD (SARA III)

CAS: 7439-92-1

RTECS: OF7525000

Fraction By Weight: 7.52%

OSHA PEL 0.05 MG/M3;1910.1025

ACGIH TLV: 0.15 MG/M3;DUST 9192

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


LEAD CHROMATE, (AS CR)

CAS: 7758-97-6

Fraction By Weight: 1.38%

OSHA PEL 0.1 MG/M3

ACGIH TLV: 0.05 MG/M3


CHROMIUM (SARA III)

CAS: 7440-47-3

RTECS: GB4200000

Fraction By Weight: 1.32%

OSHA PEL 1 MG/M3

ACGIH TLV: 0.5 MG/M3; 9192

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


TOLUENE (SARA III)

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: 10 - 30%

OSHA PEL 200 PPM/150 STEL

ACGIH TLV: 50 PPM; 9293

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


NAPHTHA, LIGHT ALIPHATIC (PETROLEUM NAPHTHA B ), VAPOR

CAS: 64742-89-8

Fraction By Weight: 15%

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:LEAD CAN BE ABSORBED THROUGH SKIN IF
MIXED W/SOLV. CR CAN BE ABSORBED THROUGH SKIN IN TOXIC AMTS (MFR).
ACUTE/INGES: SOLVS ASPIRATED INTO LUNGS CAN CAUSE CHEM PNEUMONITIS.
LEAD INTRODUCED TO MOUTH OR FROM DUST TRAPPED IN LUNGS CAN RESULT
IN FATIGUE, HDCH, LOSS OF APPETITE. CHROMIUM IS EXTREMELY (SEE EFTS
OF OVEREXP)
Explanation of Carcinogenicity:LEAD:CLASS 2B(IARC). CHROMIUM(VI):CLASS
1(IARC, NTP).
Effects of Overexposure:HLTH HAZ:IRRIT TO MOUTH, THROAT, STOMACH.
INHAL: LEAD IS IRRIT TO UPPER RESP TRACT. CHROMIUM IS SEVERELY
IRRIT TO UPPER RESP TRACT & MAY BURN MUC MEMB. SOLVS ARE
ANESTHETIC. IRRIT W/ACUTE CNS EFTS. EY E:SOLVS & LEAD ARE IRRIT.
CHROMIUM IS SEVERELY IRRIT. CHRONIC: STUDIES HAVE SHOWN TOLUENE TO
BE A BLOOD (SEE SUPP DATA)
Medical Cond Aggravated by Exposure:NONE KNOWN.

First Aid

First Aid:INGEST:DRINK 1-2 GLASSES OF WATER TO DILUTE. KEEP WARM, QUIET
& GET MD IMMED. DECISION TO INDUCE VOMIT MUST BE BASED ON ADVICE OF
MD/POISON CONTROL CENTER. NEVER GIVE ANYTHING BY MOUTH TO UNCON
PERSON . INHAL:REMOVE TO FRESH AIR. RESTORE BRTHG.GET MD. EYE:IMMED
FLUSH W/ COOL WATER LIFTING LIDS TO ENSURE THORO RINSING. CONTINUE
FOR AT LEAST 15 MINS/GET MD.SKIN:WIPE OFF W/RAG & WASH W/SOAP &
WATER.

Fire Fighting

Flash Point:60.0F,15.6C
Lower Limits:1.0
Extinguishing Media:FOAM, CO2, DRY CHEMICAL, WATER FOG.
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP.
WATER MAY BE USED TO COOL CLOSED CNTNRS TO PREVENT PRESS BUILD-UP &
POSS AUTO-IGNIT OR EXPLO.
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHTLY CLOSED. ISOLATE FROM
HEAT,SPARKS,FLAME & ELEC EQUIP. CLOSED CNTNRS MAY EXPLODE WHEN
EXPOSED TO EXTREME HEAT. APPLICATION TO (SEE SUPP DATA)

Accidental Release

Spill Release Procedures:REMOVE SOURCES OF IGNITION. SOAK UP AND REMOVE
WITH INERT ABSORBENT MATERIAL AND NON-SPARKING TOOLS. PROVIDE
ADEQUATE VENTILATION. USE NIOSH/MSHA APPROVED VAPOR RESPIRATOR.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE UPRIGHT IN SEALED CONTAINERS AND
USE AWAY FROM HIGH TEMPERATURE, SPARKS AND FLAME. AVOID PROLONGED
CONTACT WITH SKIN.
Other Precautions:DO NOT INGEST. KEEP CONTAINER TIGHTLY SEALED WHEN NOT
IN USE. KEEP OUT OF REACH OF CHILDREN.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPRVD RESPIRATORY PROTECTION.
NORMAL USE:MECHANICAL FILTER RESPIRATOR. IF MATERIAL IS HEATED OR
CONFINED SPACE:AIRLINE RESPIRATOR (POSITIVE PRESSURE).
Ventilation:MECHANICAL/GENERAL AND/OR LOCAL EXHAUST AS NEEDED TO
MAINTAIN EXPOSURES BELOW ESTABLISHED LIMITS.
Protective Gloves:SYNTHETIC RUBBER GLOVES RECOMMENDED.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:PROTECTIVE OVERALLS RECOMMENDED. REMOVE &
WASH CONTAM CLTHG. DISCARD CONTAM SHOES.
Work Hygienic Practices:WASH HANDS THOROUGHLY AFTER USE AND BEFORE
EATING, SMOKING OR USING SANITARY FACILITIES .
Supplemental Safety and Health
EXPLO HAZ:HOT SURFACES REQUIRES SPECIAL PREC. DURING EMERGENCY COND,
OVEREXPOS TO DECOMP PRODS MAY CAUSE HLTH HAZ. GET MED ATTN. HLTH
HAZ:TOXIN (MFR). LEAD IS A CUMULATIVE POISON & A PROVEN HUMAN CARC
INOGEN. CHRONIC EXPOS CAUSES BLOOD DMG (ANEMIA), DIGESTIVE/ NERVOUS
SYSTEM DMG. POSSIBLE PARALYSIS & (SEE INGRED 7)

Chemical Properties

HCC:F3
Boiling Pt:B.P. Text:230F,110C
Vapor Density:HVR/AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:65.3

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS, ACIDS, BASES.
Stability Condition to Avoid:HIGH TEMPERATURE
Hazardous Decomposition Products:MAY PRODUCE FUMES WHEN HEATED TO
DECOMPOSITION. FUMES MAY CONTAIN CO, CO2 AND NO2.

Disposal

Waste Disposal Methods:DISPOSE IN SEALED METAL CONTAINER AWAY FROM HEAT
& FLAME I/A/W FEDERAL, STATE AND LOCAL REGULALTIONS. DO NOT
INCINERATE CLOSED CONTAINERS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.